Boost Tracer Specifikace

Procházejte online nebo si stáhněte Specifikace pro Napájecí adaptéry a střídače Boost Tracer. Boost Tracer Specifications [de] [es] [fr] [pt] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 26
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
TRACER 1206/1210/1215
——Maximum Power Point Tracking Controller
Installation and Operation Manual
Thanks very much for selecting our products
This manual offers important information and suggestions with respect to
installation, operating, and troubleshooting, etc. Please read this manual carefully
before using the product and pay attention to the safety information.
Zobrazit stránku 0
1 2 3 4 5 6 ... 25 26

Shrnutí obsahu

Strany 1 - TRACER 1206/1210/1215

TRACER 1206/1210/1215 ——Maximum Power Point Tracking Controller Installation and Operation Manual Thanks very much for selecting our pr

Strany 2 - TRACER Dimensions

7 Connect load positive (+) and negative (-) to the TRACER load output as shown in figure 3-2. An in-line fuse holder should be wired in series in

Strany 3 - Contents

8 Step 3:Solar Wiring WARNING: Risk of electric shock! Exercise caution when handling solar wiring. The solar module(s) high voltage output can cau

Strany 4

9 Figure3-5 System Wiring Review Step 6: Install Fuses Install a more than15 Amp DC-rated fuse in each fuse holder in the following order: 1. Loa

Strany 5 - 2 General Information

10 4 Operation 4.1 MPPT Technology The TRACER utilizes Maximum Power Point Tracking technology to extract maximum power from the solar modu

Strany 6

11 Figure 4-1 shows a typical current VS. voltage output curve for a nominal 12V off-grid module. Current VS. Voltage in 12V system

Strany 7 - 3 Installation Instructions

12 Figure 4-2 shows the sequence of the stages. Figure 4-2 TRACER MPPT charging algorithm ·Bulk Charge In this stage, the battery voltage has not

Strany 8

13 ·Equalize WARNING: Risk of explosion! Equalizing flooded battery can produce explosive gases, so well ventilation of b

Strany 9 - Step 1: Load Wiring

14 ·Charging State Indicator The green LED indicator will light whenever sunlight is available for battery charging, the green charging LED will sta

Strany 10

15 4.4 Setting Operation . Load Control Settings 1. Dusk to Dawn (Light ON+Light OFF) When solar module voltage goes below the point of N

Strany 11

16 Press the Setting Switch, and the led will switch between load 1 timer, load 2 timer and battery type. Press the Setting Switch for 5 seconds w

Strany 12 - Confirm Power-up

TRACER Dimensions Specification Summary System Voltage 12V DC / 24V DC*1 Rated Battery

Strany 13 - 4 Operation

17 If either of the two loads is TEST MODE. The two loads will be TEST MODE simultaneously.

Strany 14

18 ·Load Short Circuit Fully protected against load wiring short-circuit. After two automatic load reconnect attempts (10 seconds between each attem

Strany 15

19 5.2 Troubleshooting Troubleshooting according to the following instructions: Faults Possible reasons Troubleshooting Charging LED indicator is

Strany 16

20 Note:If no charging LED indication when the connection is normal Measure the PV input voltage at the PV terminals, input voltage must be greate

Strany 17 - ·Charging State Indicator

21 6 Warranty The TRACER-MPPT charge controller is warranted to be free from defects for a period of TWO (2) years from the date of shipme

Strany 18

22 7 Technical Specifications • Electrical Description Parameter Nominal system voltage 12VDC or 24VDC Rated battery current 10A Battery voltage ran

Strany 19

23 • Threshold Voltage Description Parameter NTTV (Night Time Threshold Voltage) 5V; x2/24V DTTV (Day Time Threshold Voltage) 6V; x2/24V Table7-3 T

Strany 20

Contents 1 Important Safety Information ... 1 2 General Information ...

Strany 21

1 1 Important Safety Information Save These Instructions This manual contains important safety, installation and operating instructions for TRACER.

Strany 22 - press the switch button

2 2 General Information 2.1 Overview Thank you for selecting the TRACER controller which represents advanced technology of our company. The

Strany 23

3 The features of TRACER controller are shown in Figure 2-1 Figure 2-1 TRACER features. 1 – Charging status LED An LED indicator th

Strany 24 - 6 Warranty

4 2.2 Optional Accessories Remote Meter(Model:MT-2) The digital Remote Meter displays system operating information, error indications, and self-diag

Strany 25 - 7 Technical Specifications

5 Step 1: Choose Mounting Location Locate the TRACER on a vertical surface protected from direct sun, high temperature, and water. Step 2: Check for

Strany 26

6 NOTE: The TRACER is a negative ground controller. Any combination of negative connections can be earth grounded as required. Grounding is reco

Komentáře k této Příručce